Product Specification
10 KVA  3 Phase Isolation Transformer
Isolation Transformer and Ultra Isolation Transformer
New gold Isolation and Ultra transformer, control transformer, Auto transformer (Single Phase, Two Phase and Three Phase). This transformer can also be developed into step up and step down. The voltage range is 10 V to 5000 volt, and frequency 25 Hz to 500 Hz (General use 50 Hz and 60 Hz)

These isolation transformers reduce the effects of power line problems like noise, spikes, surges transients and neutral to a minimum.

Care Description of Machine and Instrument
Switching of electrical utilities in industrial and commercial environment generates spikes up to 6000 volt and high frequency power line noises.
The spikes can cause the failure of thrusters, micro processors, or other active electronic device.
The high frequency noises can interfere with digital electronic equipment causing data corruption, erratic behavior, loss or memory etc.
The noise cut off transformer eliminates such noises and attenuates the spikes to negligible values, providing complete protection against such electrical disturbances.

Application
  • Protect the CNC machines, computer and telecommunications equipment from damage due to electrical noise, spikes etc.
  • Where ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies.
  • Where ground of the equipment cannot be earthed.
  • When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls where only less then 100 micro Amps is only permitted.
  • To protect against strong lighting, impulse noise, bus short circuit accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment.
  • To shield large number of electronic equipment which individually also are producing different type of electrical noise at a common bus bar typically CNC machines, Drives, hardening equipment etc.
Technical Specification
System connections voltage design as per customer require voltage 10 volt to 5000 volt in single phase and three phase Design for frequency 25 Hz to 500 Hz (General use 47 Hz to 60 Hz)
Delta/star, star/delta, star/star(and in single phase series and panel connection)
Ratios
1:1 and 2:1 (or as per customer requirement)
Regulation
Better than 3.5%
Di-electric strength
2500 VAC for 120 Sec
Insulation Resistance
More than 1000 Mega Ohms.
Coupling Capacitance
0.1 PF for 100 db
Leakage Current
Less than 20 Micro Amps.
Common Model attenuation
100 db
Construction Standards
As per IS 2026 part I and II.
We Can Design and Manufacture As Per Customer Specification.
Other Products in 'Isolation Transformers' category
HT Transformer Uit Type
HT Transformer Uit Type
Ultra Isolation Transformer
Ultra Isolation Transformer
 
<< Back
 
 
Contact Details
SHRI GURU NANAK ELECTRICAL ENGINEERING WORKS
D-87, Sudarshan Park, (Near Tyagi Dharamshala), New Delhi - 110015, India
Phone:91-11-25413041/25116870
Fax:91-11-25116870
Send Mail  
Contact Now
Key Personnel
Mr. Rajinder Singh Rooprai (Proprietor)
Mobile:+919810076381

 
 
 
Copyright © 2009 by SHRI GURU NANAK ELECTRICAL ENGINEERING WORKS All Rights Reserved.